2019-02-01 PeC: removed from citation under the LVD, TC confirmed it is a test method standard

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2019-02-01 PeC: removed from citation under the LVD, TC confirmed it is a test method standard

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62275:2018 specifies requirements for metallic, non-metallic and composite cable ties and their associated fixing devices used for the management and support of wiring systems in electrical installations.
This third edition cancels and replaces the second edition published in 2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) consideration of adhesive fixing devices,
b) revised and updated normative references,
c) modified definitions for metallic and composite cable ties,
d) new definitions,
e) improvement of test procedures,
f) new figures for typical arrangement of test assembly for fixing devices and for integral fixing devices.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63044-5-1:2017 is a product family standard that sets the minimum level of EMC performance for the HBES/BACS network in addition to the product EMC standards for HBES/BACS devices. It also applies to devices used within an HBES/BACS network for which no specific HBES/BACS product EMC standard exists. In addition, it defines EMC requirements for the interface of equipment intended to be connected to an HBES/BACS network. It does not apply to interfaces to other networks.
NOTE An example of other networks is a dedicated ICT network covered by CISPR 22 and 23.
This document provides general performance requirements and test set-ups. This document is applicable (but not limited) to


       

  •       operator stations and other human–system interface devices,

  •    

  •       devices for management functions,

  •    

  •       control devices, automation stations and application-specific controllers,

  •    

  •       field devices and their interfaces,

  •    

  •       cabling and interconnection of devices,


used within a dedicated HBES/BACS network.
  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63044-5-3:2017 is a product family standard that sets the minimum level of EMC performance for the HBES/BACS network in addition to the product EMC standards for HBES/BACS devices. It also applies to devices used within an HBES/BACS network for which no specific HBES/BACS product EMC standard exists. In addition, it defines EMC requirements for the interface of equipment intended to be connected to an HBES/BACS network. It does not apply to interfaces to other networks.
NOTE An example of other networks is a dedicated ICT network covered by CISPR 22 and 23.
This document specifies EMC requirements for HBES/BACS to be installed in industrial environments, according to the definition given in IEC 61000-6-2.
NOTE Industrial environment covers the office spaces that may be present in industrial premises. Industrial automation systems are outside the scope. This document is applicable (but not limited) to


       

  •       operator stations and other human–system interface devices,

  •    

  •       devices for management functions,

  •    

  •       control devices, automation stations and application-specific controllers,

  •    

  •       field devices and their interfaces,

  •    

  •       cabling and interconnection of devices,


used within a dedicated HBES/BACS network. This publication is to be read in conjunction with IEC 63044-5-1:2017.
  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63044-5-2:2017 is a product family standard that sets the minimum level of EMC performance for the HBES/BACS network in addition to the product EMC standards for HBES/BACS devices. It also applies to devices used within an HBES/BACS network for which no specific HBES/BACS product EMC standard exists. In addition, it defines EMC requirements for the interface of equipment intended to be connected to an HBES/BACS network. It does not apply to interfaces to other networks.
NOTE An example of other networks is a dedicated ICT network covered by CISPR 22 and 23.
This document specifies EMC requirements for HBES/BACS to be installed in residential, commercial and light-industrial environments, according to the definition given in IEC 61000-6-1.
This document is applicable (but not limited) to


       

  •       operator stations and other human–system interface devices,

  •    

  •       devices for management functions,

  •    

  •       control devices, automation stations and application-specific controllers,

  •    

  •       field devices and their interfaces,

  •    

  •       cabling and interconnection of devices,


used within a dedicated HBES/BACS network. This publication is to be read in conjunction with IEC 63044-5-1:2017.
  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2018-11-02 - assessment is now 'compliant', BT route to be followed to adress annex ZZ
2018-08-13: non complinat assessment
2018-05-18 - Sent to HAS
2018-03-22 - TC request to BT to keep ratification pending until Annex ZZ is available
(TC213 Plenary decision to prepare Annex ZZ and associated risk assessment for submission to CCMC and to update BT (See Decision 2 in TC213/Sec1214/RM).
2017-05-16 - Cannot allocate for publication due to missing assessment from Consultant.
2016-12-12 - Annex ZZ delivered by TC and to be sent to Consultant when FDIS starts and included in lt file for NC's voting period.

  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to electrical and electronic apparatus intended for use in residential, commercial and light-industrial environments. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies where no requirements are specified. This generic EMC immunity standard is applicable if no relevant dedicated product or product-family EMC immunity standard exists. This standard applies to apparatus intended to be directly connected to a low-voltage public mains network or connected to a dedicated DC source which is intended to interface between the apparatus and the low-voltage public mains network. This standard applies also to apparatus which is battery operated or is powered by a non-public, but non-industrial, low-voltage power distribution system if this apparatus is intended to be used in the locations described below. The environments encompassed by this standard are residential, commercial and light-industrial locations, both indoor and outdoor. The following list, although not comprehensive, gives an indication of locations which are included: - residential properties, for example houses, apartments; - retail outlets, for example shops, supermarkets; - business premises, for example offices, banks; - areas of public entertainment, for example cinemas, public bars, dance halls; - outdoor locations, for example petrol stations, car parks, amusement and sports centres; - light-industrial locations, for example workshops, laboratories, service centres. Locations which are characterised by being supplied directly at low voltage from the public mains network are considered to be residential, commercial or light-industrial. The immunity requirements have been selected to ensure an adequate level of immunity for apparatus at residential, commercial and light-industrial locations. The levels do not, however, cover extreme cases, which may occur at any location, but with an extremely low probability of occurrenc

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    24 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

contains Common Modifications to IEC 60728-11:2016 (the RD for EN 60728-11:2017) in response to the comments raised by the LVD New Approach Consultant in his negative assessment of IEC 60728-11.

  • Amendment
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEW!IEC 61000-3-2:2018 is available as IEC 61000-3-2:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 61000-3-2:2018 deals with the limitation of harmonic currents injected into the public supply system. It specifies limits of harmonic components of the input current which can be produced by equipment tested under specified conditions. It is applicable to electrical and electronic equipment having a rated input current up to and including 16 A per phase, and intended to be connected to public low‑voltage distribution systems. Arc welding equipment which is not professional equipment, with a rated input current up to and including 16 A per phase, is included in this document. Arc welding equipment intended for professional use, as specified in IEC 60974-1, is excluded from this document and can be subject to installation restrictions as indicated in IEC 61000-3-12. The tests according to this document are type tests. For systems with nominal voltages less than but not equal to 220 V (line-to-neutral), the limits have not yet been considered.
This fifth edition cancels and replaces the fourth edition published in 2014. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a)   an update of the emission limits for lighting equipment with a rated power ≤ 25 W to take into account new types of lighting equipment;
b)   the addition of a threshold of 5 W under which no emission limits apply to all lighting equipment;
c)   the modification of the requirements applying to the dimmers when operating non‑incandescent lamps;
d)   the addition of test conditions for digital load side transmission control devices;
e)   the removal of the use of reference lamps and reference ballasts for the tests of lighting equipment;
f)    the simplification and clarification of the terminology used for lighting equipment;
g)   the classification of professional luminaires for stage lighting and studios under Class A;
h)   a clarification about the classification of emergency lighting equipment;
i)    a clarification for lighting equipment including one control module with an active input power ≤ 2 W;
j)    an update of the test conditions for television receivers;
k)   an update of the test conditions for induction hobs, taking also into account the other types of cooking appliances;
l)    for consistency with IEC 61000-3-12, a change of the scope of IEC 61000-3-2 from equipment with an input current ≤ 16 A to equipment with a rated input current ≤ 16 A.
Keywords: harmonic currents

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    39 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

IEC 60728-11:2016 deals with the safety requirements applicable to fixed sited systems and equipment. As far as applicable, it is also valid for mobile and temporarily installed systems, for example, caravans. This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Correction of minimum cross-section of bonding conductor in Figure 6, Figure 14 and Figure 17.
- Creation of new symbols for "overvoltage protective device - (OPD)" and for "coaxial overvoltage protective device - (COPD)".
- Introduction of new OPD symbol to 3.2, Figure 3 and Figure 6.
- Introduction of new COPD symbol to 3.2 and Figure 19.
- In 3.1 replacement of terms CATV, MATV and SMATV by new terms and definitions due to changes in technology and use of cable networks.
- Extension for remote feeding voltage on subscriber feeder.
- Adaption to Edition 2.0 of the IEC 62305 series.
- Deletion of informative Annex C and normative reference to the simplified software for the calculation of risk due to lightning (Annex J of IEC 62305-2:2006.)
- New subclause 10.2.6 Fully-isolated system outlet provided by means of a FTTH system.

  • Standard
    94 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62949:2017 applies to the interface of equipment designed and intended to be connected as a communication terminal to an information and communication technology (ICT) network termination.
This document does not apply to:
- equipment covered by IEC 62368-1; or
- interfaces to other networks.
This document specifies the safety requirements of the interface to the ICT network only. Requirements additional to those specified in this document may be necessary for equipment intended for operation while exposed, for example, to extremes of temperature, to excessive dust, moisture, or vibration, to flammable gases, to corrosive or explosive atmospheres and electro medical applications with physical connections to the patient. The following requirements are not covered by this document:
- functional safety of equipment;
- functional reliability of equipment;
- communication facilities with remote supply using hazardous voltage;
- protection of equipment connected to ICT networks from functional damage.
Key words: Audio/video, Communication Terminal. ICT Network, External Circuits

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61140:2016 applies to the protection of persons and livestock against electric shock. The intent is to give fundamental principles and requirements which are common to electrical installations, systems and equipment or necessary for their coordination, without limitations with regard to the magnitude of the voltage or current, or the type of current, and for frequencies up to 1 000 Hz. It has the status of a basic safety publication in accordance with IEC Guide 104. This fourth edition cancels and replaces the third edition published in 2001 and Amendment 1:2004. This edition constitutes a technical revision.

  • Standard
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    62 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

2014-06-10 GVN: Tolerance allocated on Secretary's request (see tcminares on 2014-06-10).
D145/080: NWI approved

  • Amendment
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

CISPR 32:2015 is available as <a href="https://webstore.iec.ch/publication/22244">CISPR 32:2015 RLV</a> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.<br />
<br />
CISPR 32:2015 applies to multimedia equipment (MME) as defined in 3.1.24 and having a rated r.m.s. AC or DC supply voltage not exceeding 600 V. This publication covers two classes of MME (Class A and Class B). The MME classes are specified in Clause 4. The objectives of this publication are:<br />
1) to establish requirements which provide an adequate level of protection of the radio spectrum, allowing radio services to operate as intended in the frequency range 9 kHz to 400 GHz;<br />
2) to specify procedures to ensure the reproducibility of measurement and the repeatability of results.<br />
This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. The contents of the corrigendum of June 2016 have been included in this copy.

  • Standard
    107 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    105 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

This EMC product-family standard, for immunity requirements, applies to the components of the following alarm systems, intended for use in and around buildings in residen¬tial, commercial, light industrial and industrial environments:
–   access control systems, for security applications;
–   alarm transmission systems 1);
–   CCTV systems, for security applications;
–   fire detection and fire alarm systems;
–   hold-up alarm systems;
–   intruder alarm systems;
–   social alarm systems;
The tests and severities to be used are the same for indoor and outdoor applications of fixed, movable and portable equipment.
The levels do not cover extreme cases, which may occur in any location, but with an extremely low probability of occurrence, or in special locations close to powerful emitters (e.g. radar transmitters).
Equipment within the scope of this standard should be designed in order to operate satisfactorily in the environmental electromagnetic conditions of residential, commercial, light industrial and industrial environments. This implies particularly that it should be able to operate correctly within the conditions fixed by the electromagnetic compatibility levels for the various disturbances on the low voltage public supply system as defined by EN 61000 2 2. The immunity tests in this standard only concern the most critical disturbance phenomena.
For equipment using radio signalling, mains signalling or with connections to the public telephone system, additional requirements, from other standards specific to these signalling media, might apply.
This standard does not specify basic safety requirements, such as protection against electrical shocks, unsafe operation, insulation coordination and related dielectric tests.
This standard does not cover EMC emission requirements. These are covered by other appropriate standards.

  • Amendment
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60825-1:2014 is applicable to safety of laser products emitting laser radiation in the wavelength range 180 nm to 1 mm. A laser product may consist of a single laser with or without a separate power supply or may incorporate one or more lasers in a complex optical, electrical, or mechanical system. Typically, laser products are used for demonstration of physical and optical phenomena, materials processing, data reading and storage, transmission and display of information, etc. Such systems have found use in industry, business, entertainment, research, education, medicine and consumer products. Laser products that are sold to other manufacturers for use as components of any system for subsequent sale are not subject to IEC 60825-1, since the final product will itself be subject to this standard. Laser products that are sold by or for manufacturers of end products for use as repair parts for the end products are also not subject to IEC 60825-1. However, if the laser system within the laser product is operable when removed from the end product, the requirements of this Part 1 apply to the removable laser system. The objectives of this part of IEC 60825 are:
- to introduce a system of classification of lasers and laser products emitting radiation in the wavelength range 180 nm to 1 mm according to their degree of optical radiation hazard in order to aid hazard evaluation and to aid the determination of user control measures;
- to establish requirements for the manufacturer to supply information so that proper precautions can be adopted;
- to ensure, through labels and instructions, adequate warning to individuals of hazards associated with accessible radiation from laser products; and
- to reduce the possibility of injury by minimizing unnecessary accessible radiation and to give improved control of the laser radiation hazards through protective features. This edition includes the following significant technical changes with respect to the previous edition:
- a new class, Class 1C, was introduced;
- the measurement condition 2 ("eye loupe" condition) was removed;
- a classification of the emission of laser products below a certain radiance level that are intended to be used as replacement for conventional light sources can, as an option, be based on the IEC 62471 series;
- and the accessible emission limits (AELs) for Class 1, 1M, 2, 2M and 3R of pulsed sources, particularly of pulsed extended sources, were updated to reflect the latest revision of the ICNIRP guidelines on exposure limits (accepted for publication in Health Physics Journal 2013, see also www.icnirp.org).

  • Standard
    117 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    108 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60754-1:2011 specifies the apparatus and procedure for the determination of the amount of halogen acid gas, other than hydrofluoric acid, evolved during the combustion of compounds based on halogenated polymers and compounds containing halogenated additives taken from electric or optical fibre cable constructions. The method specified in this standard is intended for the testing of individual components used in a cable construction. The use of this method will enable the verification of requirements which are stated in the appropriate cable specification for individual components of a cable construction. The significant technical changes with respect to the previous edition are as follows:   - improved definition of safety requirements relating to capture of gases and use of reagents;  - introduction of guidance on preparation of test specimens for a more even combustion;  - improvements to the procedure for establishing the heating regime;  - improved expression of tolerances and precision;  - definition of the procedure for the blank test;  - introduction of an informative annex giving details of a methodology for the determination of the halogen acid gas content of a sample representative of a cable construction.   IEC 60754-1:2011 Has the status of a group safety publication in accordance with IEC Guide 104.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60754-2:2011 specifies the apparatus and procedure for the determination of the potential corrosivity of gases evolved during the combustion of materials taken from electric or optical fibre cable constructions by measuring the acidity (pH) and conductivity of an aqueous solution resulting from the gases evolved during the combustion. The general method specified in this standard is intended for the testing of individual components used in a cable construction. Formulae are given for the calculation of a weighted value for a combination of materials found in a specified cable. The use of this method will enable the verification of relevant requirements for either individual components or combined components of a cable construction stated in the appropriate cable specification. A simplified method is included for the testing of individual components where it is required only to demonstrate compliance with a stated performance requirement for quality control purposes. The significant technical changes with respect to the previous edition are as follows:   - improved definition of safety requirements relating to capture of gases;  - introduction of guidance on the preparation of test specimens for more even combustion;  - better expression of tolerances and precision;  - clarification of the conductivity and acidity functions;  - improved definition of the heating procedure;  - greater precision in the definition of the test temperature for the determination of pH value and conductivity;  - correction of the formulae for the calculation of the test results.  IEC 60754-2:2011 has the status of a group safety publication in accordance with IEC Guide 104.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 50561 specifies limits and methods of measurement of radio disturbance characteristics for in-home communication apparatus that use the low-voltage power installation as the transmission medium. This part of EN 50561 applies to equipment that communicate over this medium in the frequency range 1,606 5 MHz to 30 MHz.
NOTE   Similar equipment that communicate outside this frequency range is under study and will be covered by another European Standard.
Procedures are given for the measurement of signals generated by the equipment and limits are specified for the frequency range 9 kHz to 400 GHz. No measurement is required at frequencies where no limit is specified.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    28 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

NEW! IEC 61000-3-3:2013 is available as IEC Standards+ 61000-3-3:2013 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.  IEC 61000-3-3:2013 is concerned with the limitation of voltage fluctuations and flicker impressed on  the public low-voltage system. It specifies limits of voltage changes which may be produced by an equipment tested under specified conditions and gives guidance on methods of assessment. It is applicable to electrical and electronic equipment having an input current equal to or less than 16 A per phase, intended to be connected to public low-voltage distribution systems of between 220 V and 250 V line to neutral at 50  Hz, and not subject to conditional connection. IEC 61000-3-3 has the status of a product family standard within the IEC 61000 series. This third edition cancels and replaces the second edition published in 2008. This  edition constitutes a technical revision which takes account of the changes made in IEC 61000-4-15:2010.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    37 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical
equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V a.c. and 1 500 V d.c. This standard does not apply to conduit systems, cable tray systems, cable ladder systems, power track systems or equipment covered by other standards. This Part 1 shall be used in conjunction with the relevant Part 2 for particular requirements.

  • Amendment
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   General
Standards of the EN 50083 and EN 60728 series deal with cable networks including equipment and associated methods of measurement for headend reception, processing and distribution of television signals, sound signals and their associated data signals and for processing, interfacing and transmitting all kinds of signals for interactive services using all applicable transmission media.
This includes
•   CATV-networks  ),
•   MATV-networks and SMATV-networks,
•   individual receiving networks
and all kinds of equipment, systems and installations installed in such networks.
The extent of this standardisation work is from the antennas and/or special signal source inputs to the headend or other interface points to the network up to the terminal input.
The standardisation of any user terminals (i.e., tuners, receivers, decoders, multimedia terminals, etc.) as well as of any coaxial, balanced and optical cables and accessories thereof is excluded.
1.2   Specific scope of EN 50083 2
This European Standard
•   applies to the radiation characteristics and immunity to electromagnetic disturbance of EM active equipment (active and passive equipment) for the reception, processing and distribution of television, sound and interactive multimedia signals as dealt with in the following parts of EN 50083 or EN 60728 series:
–   EN 60728-3   "Active wideband equipment for cable networks";
–   EN 60728-4   "Passive wideband equipment for coaxial cable networks";
–   EN 60728-5   "Headend equipment";
–   EN 60728-6   "Optical equipment";
•   covers the following frequency ranges:
disturbance voltage injected into the mains   150 kHz to 30 MHz;
radiation from active equipment    5 MHz to 25 GHz;
immunity of active equipment   150 kHz to 25 GHz  );
screening effectiveness of passive equipment   5 MHz to 3,5 GHz    (25 GHz)  );
•   specifies requirements for maximum allowed radiation, minimum immunity and minimum screening effectiveness;
•   describes test methods for conformance testing.

  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    57 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-3-12:2011 deals with the limitation of harmonic currents injected into the public supply system. The limits given in this International Standard are applicable to electrical and electronic equipment with a rated input current exceeding 16 A and up to and including 75 A per phase, intended to be connected to public low-voltage a.c. distribution systems of the following types:  - nominal voltage up to 240 V, single-phase, two or three wires;  - nominal voltage up to 690 V, three-phase, three or four wires;  - nominal frequency 50 Hz or 60 Hz. Other distribution systems are excluded. The limits given in this edition apply to equipment when connected to 230/400 V, 50 Hz systems. This standard applies to equipment intended to be connected to low-voltage systems interfacing with the public supply at the low-voltage level. It does not apply to equipment intended to be connected only to private low-voltage systems interfacing with the public supply only at the medium- or high-voltage level. This standard defines:  a) requirements and emission limits for equipment;  b) methods for type tests and simulations. Tests according to this International Standard are type tests of complete pieces of equipment. Conformity with this standard can also be determined by validated simulations. This second edition cancels and replaces the first edition published in 2004 and constitutes a technical revision. The significant technical changes with respect to the previous edition are:  - the replacement of the reference fundamental current I1 by the reference current Iref for the calculation of emission limits; - a new added table of current emission limits (Table 5);  - a new added annex (Annex A) to define test conditions for some types of equipment;  - Deletion of the former Annexes B (Approximate interpolation formulas) and D (Information on the PWHD factor).

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    29 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

This EMC product-family standard, for immunity requirements, applies to the components of the following alarm systems, intended for use in and around buildings in residential, commercial, light industrial and industrial environments: - access control systems, for security applications; - alarm transmission systems 1); - CCTV systems, for security applications; - fire detection and fire alarm systems; - hold-up alarm systems; - intruder alarm systems; - social alarm systems; The tests and severities to be used are the same for indoor and outdoor applications of fixed, movable and portable equipment. The levels do not cover extreme cases, which may occur in any location, but with an extremely low probability of occurrence, or in special locations close to powerful emitters (e.g. radar transmitters). Equipment within the scope of this standard should be designed in order to operate satisfactorily in the environmental electromagnetic conditions of residential, commercial, light industrial and industrial environments. This implies particularly that it should be able to operate correctly within the conditions fixed by the electromagnetic compatibility levels for the various disturbances on the low voltage public supply system as defined by EN 61000-2-2. The immunity tests in this standard only concern the most critical disturbance phenomena. For equipment using radio signalling, mains signalling or with connections to the public telephone system, additional requirements, from other standards specific to these signalling media, might apply. This standard does not specify basic safety requirements, such as protection against electrical shocks, unsafe operation, insulation coordination and related dielectric tests. This standard does not cover EMC emission requirements. These are covered by other appropriate standards.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Amandma A2:2011 je dodatek k standardu SIST EN 60825-4:2008.
This part of IEC 60825 specifies the requirements for laser guards, permanent and temporary (for example for service), that enclose the process zone of a laser processing machine, and specifications for proprietary laser guards. This standard applies to all component parts of a guard including clear (visibly transmitting) screens and viewing windows, panels, laser curtains and walls. Requirements for beam path components, beam stops and those other parts of a protective housing of a laser product which do not enclose the process zone are contained in IEC 60825-1. In addition this part of IEC 60825 indicates: a) how to assess and specify the protective properties of a laser guard; and b) how to select a laser guard.

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61000 for EMC emission requirements applies to electrical and electronic apparatus intended for use in industrial environments as described below. Emission requirements in the frequency range 0 Hz to 400 GHz are covered. No measurement needs to be performed at frequencies where no requirement is specified. This generic EMC emission standard is applicable if no relevant dedicated product or productfamily EMC emission standard exists. This standard applies to a apparatus intended to be connected to a power network supplied from a high or medium voltage transformer dedicated to the supply of an installation feeding manufacturing or similar plant, and intended to operate in or in proximity to industrial locations, as described below. This standard applies also to apparatus, which is battery operated and intended to be used in industrial locations. The environments encompassed by this standard are industrial, both indoor and outdoor. Industrial locations are in addition characterised by the existence of one or more of the following examples: - industrial, scientific and medical (ISM)1)) apparatus; - heavy inductive or capacitive loads that are frequently switched; - high currents and associated magnetic fields. The object of this standard is to define the emission test requirements for apparatus defined in the scope in relation to continuous and transient, conducted and radiated disturbances. The emission requirements have been selected so as to ensure that disturbances generated by apparatus operating normally in industrial locations do not exceed a level that could prevent other apparatus from operating as intended. Fault conditions of apparatus are not taken into account. Not all disturbance phenomena have been included for testing purposes in this standard but only those considered as relevant for the equipment covered by this standard. These requirements represent essential electromagnetic compatibility emission requirements.

  • Standard – translation
    16 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Defines the immunity test requirements for information technology equipment (ITE, as defined in CISPR 22) in relation to continuous and transient, conducted and radiated disturbances, including electrostatic discharges (ESD). Procedures are defined for the measurement of ITE and limits are specified which are developed for ITE and within the frequency range from 0 Hz to 400GHz.This publication establishes requirements which will provide an adequate level of intrinsic immunity so that the equipment will operate as intended in its environment. The test requirements are specified for each port considered.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The scope of EN 50491 5 1:2010 applies, with the following modification:
Replace the 3rd paragraph by the following ones:
This is the specific part of EN 50491-5 for HBES/BACS used in residential, commercial and light industry environment.
The environments covered by this standard are residential, commercial and light-industrial locations, according to the definition in EN 61000-6-1.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies requirements and tests for conduit systems buried underground including conduits and conduit fittings for the protection and management of insulated conductors and/or cables in electrical installations or in communication systems. This standard applies to metallic, non-metallic and composite systems including threaded and non-threaded entries which terminate the system.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This product family standard sets the minimum level of EMC performance for HBES/BACS products intended to be connected to an HBES/BACS system.  A set of devices connected to perform a stand alone application is not considered to be an HBES/BACS system and therefore are outside the scope of this European Standard. This European Standard provides the general performance requirements and test setups for EMC for all products connected to HBES/BACS.  This connection can be wired (e.g. communication cable, power line) or wireless (e.g. radiofrequency, infrared). This European Standard is applicable (but not limited) to –   operator stations and other human system interface devices, –   devices for management functions, –   control devices, automation stations and application specific controllers, –   field devices and their interfaces, –   cabling and interconnection of devices, –   dedicated devices for engineering and commissioning tools for HBES/BACS

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The scope of EN 50491-5-1:2010 applies, with the following modification:
Replace the 3rd paragraph with the following ones:
This is the specific part of EN 50491-5 for HBES/BACS used in industry environment.
The environment covered by this standard is industrial, according to the definition in EN 61000-6-2.

  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V a.c. and 1 500 V d.c. Slotted cable trunking systems are intended for mounting inside cabinets in electrical and/or communication system installations. This European Standard does not apply to conduit systems, cable tray systems, cable ladder systems, power track systems or equipment covered by other standards. This European Standard shall be used in conjunction with EN 50085-1:2005 “Cable trunking systems and cable ducting systems for electrical installations – Part 1: General requirements” which is referred to in this document as Part 1. Wherever reference is made in this European Standard to EN 50085 1:2005 this does not apply to cable ducting systems.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60825 specifies the requirements for laser guards, permanent and temporary (for example for service), that enclose the process zone of a laser processing machine, and specifications for proprietary laser guards. This standard applies to all component parts of a guard including clear (visibly transmitting) screens and viewing windows, panels, laser curtains and walls. Requirements for beam path components, beam stops and those other parts of a protective housing of a laser product which do not enclose the process zone are contained in IEC 60825-1. In addition this part of IEC 60825 indicates: a) how to assess and specify the protective properties of a laser guard; and b) how to select a laser guard.

  • Amendment
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Gives guidance for evaluating the photobiological safety of lamps and lamp systems including luminaires. Specifically it specifies the exposure limits, reference measurement technique and classification scheme for the evaluation and control of photobiological hazards from all electrically powered incoherent broadband sources of optical radiation, including LEDs but excluding lasers, in the wavelength range from 200 nm through 3000 nm. This standard was prepared as Standard CIE S 009:2002 by the International Commission on Illumination.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61386 specifies requirements and tests for conduit systems, including conduits and conduit fittings, for the protection and management of insulated conductors and/or cables in electrical installations or in communication systems up to 1 000 V a.c. and/or 1 500 V d.c. This second edition cancels and replaces the first edition published in 1996, and its Amendment 1 (2000), and it constitutes a technical revision. The changes to the first edition are as follows:  - change to the length of the test specimen between fittings for the tensile test,  - editorial and normative reference updates.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to electronic and electrical equipment for which no dedicated product- or product family standard regarding human exposure to electromagnetic fields applies.  The frequency range covered is 0 Hz to 300 GHz. The object of this generic standard is to provide assessment methods and criteria to evaluate such equipment against basic restrictions or reference levels on exposure of the general public related to electric, magnetic and electromagnetic fields and induced and contact current.

  • Standard
    77 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies the requirements for laser guards, permanent and temporary (for example for service), that enclose the process zone of a laser processing machine, and specifications for proprietary laser guards. Applies to all component parts of a guard including clear (visibly transmitting) screens and viewing windows, panels, laser curtains and walls.

  • Standard
    70 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies outside diameters for conduits used in electrical installations or in communication systems and the dimensional requirements for threads. It also specifies the dimensional requirements for threads used in associated fittings. It is not applicable to extra heavy-duty electrical rigid steel conduits specified in IEC 60981. This third edition cancels and replaces the second edition published in 1993. This edition constitutes a technical revision. The following main changes have been made to the second edition: -revised figures and tables plus editorial and normative reference updates -conduit range increased to 110 mm outside diameter.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Provides requirements and specific guidance for the safe operation and maintenance of optical fibre communication systems (OFCS). In these systems optical power may be accessible outside the confinements of transmitting equipment or at great distance from the optical source. This standard requires the assessment of hazard levels at accessible locations as a replacement for classification according to IEC 60825-1. It applies to the complete installed end-to-end OFCS, including its components and subassemblies that generate or amplify optical radiation. Individual components and subassemblies that are sold only to OEM vendors for incorporation into a complete installed end-to-end OFCS need not be assessed to this standard, since the final OFCS should itself be assessed according to this standard. The objective of this Part 2 of IEC 60825 is: to protect people from optical radiation resulting from OFCS; - provide requirements for manufacturers, installation organizations, service organizations and operating organizations in order to establish procedures and supply information so that proper precautions can be adopted; - ensure adequate warnings are provided to individuals regarding the potential hazards associated with OFCS through the use of signs, labels and instructions.

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Replacement: This European Standard specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V a.c. and 1 500 V d.c. These systems are intended for mounting on walls and/or ceilings. They may be embedded, installed in a flush or semi-flush state, surface mounted or mounted away from the surface using fixing devices. This standard does not apply to conduit systems, cable tray systems, cable ladder systems, power track systems or equipment covered by other standards. This standard shall be used in conjunction with EN 50085-1:2005: Cable trunking systems and cable ducting systems for electrical installations - Part 1 General requirements which is referred to in this document as Part 1.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61000 for EMC emission requirements applies to electrical and electronic apparatus intended for use in industrial environments as described below.
Emission requirements in the frequency range 0 Hz to 400 GHz are covered. No measurement needs to be performed at frequencies where no requirement is specified.
This generic EMC emission standard is applicable if no relevant dedicated product or product-family EMC emission standard exists.
This standard applies to a apparatus intended to be connected to a power network supplied from a high or medium voltage transformer dedicated to the supply of an installation feeding manufacturing or similar plant, and intended to operate in or in proximity to industrial locations, as described below. This standard applies also to apparatus, which is battery operated and intended to be used in industrial locations.
The environments encompassed by this standard are industrial, both indoor and outdoor.
Industrial locations are in addition characterised by the existence of one or more of the following examples:
- industrial, scientific and medical (ISM) apparatus;
- heavy inductive or capacitive loads that are frequently switched;
- high currents and associated magnetic fields.
The object of this standard is to define the emission test requirements for apparatus defined in the scope in relation to continuous and transient, conducted and radiated disturbances.
The emission requirements have been selected so as to ensure that disturbances generated by apparatus operating normally in industrial locations do not exceed a level that could prevent other apparatus from operating as intended. Fault conditions of apparatus are not taken into account. Not all disturbance phenomena have been included for testing purposes in this standard but only those considered as relevant for the equipment covered by this standard. These requirements represent essential electromagnetic compatibility emission requirements.
Requirements are specified for each port considered.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    17 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies requirements and tests for cable tray systems and cable ladder systems intended for the support and accommodation of cables and possibly other electrical equipment in electrical and/or communication systems installations. Where necessary, cable tray systems and cable ladder systems may be used for the division or arrangement of cables into groups.

  • Standard
    85 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard covers the construction, requirements and particular test methods for flat, flexible PVC insulated and PVC sheathed cables, of rated voltage Uo/U 300/500 V, for use in passenger and goods lifts (elevators), and Uo/U 450/750 V for general purposes and for special applications such as hoists and travelling cranes. Cables of composite construction (for instance, cables with cores of different sizes) are not specified, but conditions are given for the inclusion of telecommunication units into the cables. NOTE 1   This revision is in accordance with an agreement with CEN TC 10 to specify in the same standard a) flexible cables for lifts as required by EN 81, and b) flexible cable for applications such as hoists and travelling cranes, previously found in HD 359. In accordance with this agreement only those cables in Clauses 5 and 6 are suitable for use with EN 81. NOTE 2   The limits for the overall diameter of the cables have been calculated in accordance with EN 60719.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   This Part 1 of the European standards series EN 50121 outlines the structure and the content of the whole set. This part alone is not sufficient to give presumption of conformity to the essential requirements of the EMC-Directive and must be used in conjunction with other parts of this standard. Annex A describes the characteristics of the railway system which affect electromagnetic compatibility (EMC) behaviour.  Phenomena excluded from the set are Nuclear EM pulse, abnormal operating conditions and the induction effects of direct lightning strike. Emission limits at the railway boundary do not apply to intentional transmitters within the railway boundaries. Safety considerations are not covered by this set of standards. The biological effects of non-ionising radiation as well as apparatus for medical assistance, such as pacemakers, are not considered here. 1.2   This European Standard is supplemented by the following specific standards: EN 50121-2      Railway applications - Electromagnetic compatibility - Part 2: Emission of the whole railway system to the outside world EN 50121-3-1      Railway applications - Electromagnetic compatibility - Part 3-1: Rolling stock - Train and complete vehicle EN 50121-3-2      Railway applications - Electromagnetic compatibility -    Part 3-2: Rolling stock - Apparatus EN 50121-4      Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus EN 50121-5      Railway applications - Electromagnetic compatibility -    Part 5: Emission and immunity of fixed power supply installations and apparatus

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies requirements for information technology equipment (ITE) with self contained data storage systems that contain hazardous moving parts. These data storage systems are typically large enough to permit a person to enter completely, however, the systems also include similar large equipment permitting complete limb or head access to the area containing hazardous moving parts. These requirements are additional to the relevant requirements in EN 60950-1.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day
OSZAR »